How do I set up the CH5200P?
Each control can be configured for throttle & shift, twin throttle, or twin shift, simply by screwing in the appropriate throttle stops, detents, and knobs that come with the control.
Shift cables must always be connected to the direct drive arm, regardless of which control station.
The Twin S (CH5200P) can be used in single or twin station applications.
Dual station setups must only utilize the shift detents and throttle stops for throttle at the station whose cables are directly connected to the engine. All cables from the "master" control to the other station(s) must be connected to the direct drive arms of secondary control(s), which must not have active throttle friction or shift detents.
In multiple stations, we recommend running the cables in series and only using Xtreme control cables.